    Inverter UPS AVR Charger, DC to DC, DC To AC Power Inverter, UPS, SMR.

    Products

    Online UPS Systems

    ups systems

    • Model No: PM-90120CP
    • Factory Location: Taiwan
    • Sample Request: No
    • Target Markets: Worldwide

    Detail Information

    Description :

    1. Character:
    -Advanced technology of PWM, DSP and IGBT switching components Designed to use a high frequency, highly efficiency DSP/IGBT and PWM technology in converting DC to AC power.
    -True Galvanic isolation design Solve ultimately the problem of power system, including noise, lightning, and leakage current etc.
    -Multi-CPU design and software/hardware cooperate control Make the system extremely high reliable.
    -Plug & Play modular design To allow for each power circuit to be easily removed for quick maintenance and troubleshooting.
    -Each phase with individual inverter supporting Characteristics will not be violated under 100% unbalance load.
    -Protection against detaching and floating of the neutral of input power supply Ensure the safety and stability of the UPS power output.
    -Protection from user error Advanced circuitry prohibits damage to the system when the user makes an operational mistake.
    -Intelligent charger with temperature compensation (option) Prolong the battery life expectancy. And with huge charging power (selectable), can charge very big capacity, long back-up time battery bank.
    -Intelligent, safe battery test circuitry Test the battery without the risk of output AC failure in case of battery bad. And with battery fluid leakage and improper grounding detect circuitry, can ensure safety of the battery bank.
    -Intelligent fan speed control Increase the fan life expectancy and reduce audible noise.
    -Reasonable heat evacuation passage design Main PCBs are designed in a holder to separate the control circuitry and power circuitry. Therefore, the UPS system can operate under harsh environment.
    -Cool start function Can be started without AC mains (with battery only) and protected from high inrush current.
    -Variety of accessory (options) Remote control panel, 3 phases software for PC monitoring, auto dialing module, battery monitoring module, 3 phases SNMP card, and emergency power-off switch are available.
    -Microprocessor design base
    -Mini- remote control panel (option)
    -Multiple output sockets
    -Minimum foot print area design, light weight
    -Built-In AVR for wider input range
    -Auto re-charging whenever AC exist.
    -Hot swappable battery by users
    -RS232 communication port
    -Tel/modem internet surge suppression
    -DC Start function
    -Green power function
    -Auto detecting frequency 12-Pulse Full Controlled Rectifier (option) To reduce total harmonic current and for UPS.

    2. Description:
    3 phase in 3 phase out online UPS.
    Intelligent, digitalized, and true galvanic isolation online design for Power Plants.

    Specification :

    MODELPM-90120CP
    CAPACITYCapacity120KVA / 96KW
    INPUT (RECTIFIER)Input Voltage220 / 380 / 460, 208/ 380, 400, 415
    Input Range±20% ( > ±20% is available upon request)
    Input Frequency50 / 60 Hz ± 5Hz
    Power Walk In0% - 100% : 20 sec
    Efficiency 98%
    Voltage Regulation±1%
    BATTERYBattery Type / PcsMaintenance free lead-acid batteries / 12V x 29pcs
    Maximum Charge
    Current Adc (Selectable)
    60
    Battery StartYes, UPS can be started without AC source.
    INVERTEROutput Voltage220 / 380 / 460, 208 / 380, 400, 415  ± 1 %
    Wave FormSine Wave
    Output Power Factor0.8
    Frequency Lock Range50 / 60 Hz ± 3Hz
    Output Frequency
    (Free Running)
    50 / 60 Hz ± 0.1 Hz
    Phase Shift Under 100% Unbalance Load< 0.5
    THD (Linear Load)< 2 %
    Overload <110%Continuous
    Overload 110-125%15 minutes
    Overload 125-150%10 minutes
    Overload >150%1 minute
    Efficiency (100% Load)95%
    STATIC SWITCHVoltage Range173-277 VAC (L-N)
    Mains ¡÷ Inverter 
    Inverter ¡÷ Mains
    0 ms
    OVERALL CHARACTERISTICSOverall Efficiency93%
    Maximum Heat 
    Dissipation (Kw)
    6.5
    Height x Width x Depth (mm)1600 x 550 x 800
    Weight 
    (Kg, without battery)
    1180
    Audible Noise< 67 dBA (At 1 M)
    Temperature0-40(32-104)
    Humidity0% - 90% (Non-Condensing)
    Altitude 
    EN50091-1,-2YES
    Short Circuit ProtectionYES
    Lightning / EMC FilterMOV / Input&Output (FCC CLASS A)
    Galvanic IsolationInput&Output true Galvanic isolation
    LED, LCD, BuzzerYES
    Remote Control / 
    Communication Interface
    Monitoring 1~99 UPS simultaneously / Dry contact, RS232, RS485

    Power Master Technology Co., Ltd.

    • Taiwan
    主站蜘蛛池模板: eeuss影院www在线观看免费| 一本一本久久a久久综合精品蜜桃| 色综合67194| 欧美人与动交片免费播放| 国内精品卡1卡2卡区别| 亚洲综合小说久久另类区| assbbwbbwbbwbbwbw精品| 狠狠噜天天噜日日噜视频麻豆 | 欧美人与牲动交xxxxbbbb| 欧美丰满熟妇xxxxx| 国产理论在线观看| 亚洲av无码一区二区三区电影| 很污很黄的网站| 日韩小视频在线观看| 国产免费怕怕免费视频观看| 久久一区二区三区免费播放| 色伦专区97中文字幕| 成人午夜免费视频免费看| 公的大龟慢慢挺进我的体内视频| www日本xxx| 污污网站在线看| 国产精品乱子乱xxxx| 五月婷婷伊人网| 草莓视频未满十八岁| 性欧美成人免费观看视| 免费人成激情视频在线观看冫| 9久热精品免费观看视频| 欧美日韩福利视频| 国产欧美日韩综合精品一区二区| 久久精品免费大片国产大片| 色综合热无码热国产| 少妇精品久久久一区二区三区 | 免费人成网站7777视频| 99久久精品免费精品国产| 欧美性受xxxx狂喷水| 国产成人午夜福利在线播放| 久久久久久亚洲av成人无码国产| 精品国产欧美另类一区| 在线观看av无需播放器| 亚洲乱码一二三四区麻豆| 试看120秒做暖暖免费体验区|