  • Power Master Technology Co., Ltd.

    Inverter UPS AVR Charger, DC to DC, DC To AC Power Inverter, UPS, SMR.

    Products

    Online UPS Systems

    ups systems

    • Model No: PM-9010CS
    • Factory Location: Taiwan
    • Sample Request: No
    • Target Markets: Worldwide

    Detail Information

    Description :

    1. Character:
    -Advanced technology of PWM, DSP and IGBT switching components Designed to use a high frequency, highly efficiency DSP/IGBT and PWM technology in converting DC to AC power.
    -True Galvanic isolation design Solve ultimately the problem of power system, including noise, lightning, and leakage current etc.
    -Multi-CPU design and software/hardware cooperate control Make the system extremely high reliable.
    -Plug & Play modular design To allow for each power circuit to be easily removed for quick maintenance and troubleshooting.
    -Each phase with individual inverter supporting Characteristics will not be violated under 100% unbalance load.
    -Protection against detaching and floating of the neutral of input power supply Ensure the safety and stability of the UPS power output.
    -Protection from user error Advanced circuitry prohibits damage to the system when the user makes an operational mistake.
    -Intelligent charger with temperature compensation (option) Prolong the battery life expectancy. And with huge charging power (selectable), can charge very big capacity, long back-up time battery bank.
    -Intelligent, safe battery test circuitry Test the battery without the risk of output AC failure in case of battery bad. And with battery fluid leakage and improper grounding detect circuitry, can ensure safety of the battery bank.
    -Intelligent fan speed control Increase the fan life expectancy and reduce audible noise.
    -Reasonable heat evacuation passage design Main PCBs are designed in a holder to separate the control circuitry and power circuitry. Therefore, the UPS system can operate under harsh environment.
    -Cool start function Can be started without AC mains (with battery only) and protected from high inrush current.
    -Variety of accessory (options) Remote control panel, 3 phases software for PC monitoring, auto dialing module, battery monitoring module, 3 phases SNMP card, and emergency power-off switch are available.
    -Microprocessor design base
    -Mini- remote control panel (option)
    -Multiple output sockets
    -Minimum foot print area design, light weight
    -Built-In AVR for wider input range
    -Auto re-charging whenever AC exist.
    -Hot swappable battery by users
    -RS232 communication port
    -Tel/modem internet surge suppression
    -DC Start function
    -Green power function
    -Auto detecting frequency 12-Pulse Full Controlled Rectifier (option) To reduce total harmonic current and for UPS.

    2. Description:
    3 phase in 3 phase out online UPS.
    Intelligent, digitalized, and true galvanic isolation online design for Power Plants.

    Specification :

    MODELPM-9010CS
    CAPACITYCapacity10KVA / 8KW
    INPUT (RECTIFIER)Input Voltage220 / 380 / 460, 208 / 380, 400, 415VY
    Input Range±20% ( > ±20% is available upon request)
    Input Frequency50 / 60 Hz ± 5Hz
    Power Walk In0% - 100% : 20 sec
    Efficiency98%
    Voltage Regulation±1%
    BATTERYBattery Type / PcsMaintenance free lead-acid batteries / 12V x 29pcs
    Maximum Charge
    Current Adc (Selectable)
    5
    Battery StartYes, UPS can be started without AC source.
    INVERTEROutput Voltage220 / 380 / 460, 208 / 380, 400, 415   ± 1 %
    Wave FormSine Wave
    Output Power Factor0.8
    Frequency Lock Range50 / 60 Hz ± 3Hz
    Output Frequency
    (Free Running)
    50 / 60 Hz ± 0.1 Hz
    Phase Shift Under 100% Unbalance Load< 0.5
    THD (Linear Load)< 2 %
    Overload <110%Continuous
    Overload 110-125%15 minutes
    Overload 125-150%10 minutes
    Overload >150%1 minute
    Efficiency (100% Load)93%
    STATIC SWITCHVoltage Range173-277 VAC (L-N)
    Mains ¡÷ Inverter 
    Inverter ¡÷ Mains
    0 ms
    OVERALL CHARACTERISTICSOverall Efficiency91%
    Maximum Heat 
    Dissipation (Kw)
    1.1
    Height x Width x Depth (mm)1600 x 550 x 800
    Weight 
    (Kg, without battery)
    300
    Audible Noise< 65 dBA (At 1 M)
    Temperature0-40 (32-104)
    Humidity0% - 90% (Non-Condensing)
    Altitude 
    EN50091-1,-2YES
    Short Circuit ProtectionYES
    Lightning / EMC FilterMOV / Input&Output (FCC CLASS A)
    Galvanic IsolationInput&Output true Galvanic isolation
    LED, LCD, BuzzerYES
    Remote Control / 
    Communication Interface
    Monitoring 1~99 UPS simultaneously / Dry contact, RS232, RS485
     

    Power Master Technology Co., Ltd.

    • Taiwan
    主站蜘蛛池模板: 一级毛片不卡免费看老司机 | 国产91精品一区| 久青草影院在线观看国产| 18岁日韩内射颜射午夜久久成人| 欧美黑人xxxx又粗又长| 在线观看无码av网站永久免费| 免费v片视频在线观看视频| 一本色综合久久| 破处视频在线观看| 女人与公拘交酡过程高清视频| 免费在线观看污污视频| videsgratis欧美另类| 男人j进女人p里动态图| 天天影视综合网色综合国产| 人妻在线无码一区二区三区| 99xxoo视频在线永久免费观看| 波多野结衣中文字幕一区二区三区| 国邦征服雪婷第二篇| 亚洲成av人片不卡无码| ww亚洲ww在线观看国产| 最近免费中文字幕完整7| 国产在线麻豆精品| 久久久xxxx| 精品国产一区二区三区AV性色| 女邻居拉开裙子让我挺进| 亚洲综合激情视频| 91亚洲va在线天线va天堂va国产| 欧美日韩三级在线观看| 国产欧美日韩综合精品一区二区| 久久精品小视频| 色yeye在线观看| 好爽好多水小荡货护士视频| 亚洲精品欧美精品日韩精品| 2020国产在线| 日韩伦理片电影在线免费观看| 国产三级在线观看完整版| 一级欧美一级日韩| 永久免费在线观看视频| 国产漂亮白嫩美女在线观看| 久久久久一区二区三区| 真实国产乱子伦高清|