<td id="kg486"><optgroup id="kg486"></optgroup></td>
<button id="kg486"><tbody id="kg486"></tbody></button>
<li id="kg486"><dl id="kg486"></dl></li>
  • <dl id="kg486"></dl>
  • <code id="kg486"><tr id="kg486"></tr></code>

  • IR-TEC International Ltd.

    Taiwan Manufacturers, Exporters.

    Products

    HEM-2 System Master Sensors

    system master sensor

    • Model No: HEM-550E
    • Factory Location: Taiwan
    • Sample Request: No
    • Target Markets: Worldwide

    Detail Information

    Description :

    1. HEM-550E is the master sensor of HEM-2 Guestroom HVAC Energy Management System. This is not only an occupancy sensor, but also a signal processor of the system.
    2. With superior detection capability, this sensor is able to detect the slightest movement of hotel guest.
    3. When guestroom is physically occupied, the HEM-550E will command PP-116 to provide power for HVAC operation.
    4. After the guestroom is vacant, the HEM-550E will command PP-116 to shut off the power for HVAC operation to reduce the energy consumption.

    Specification :

    1. Power supply 24 2 VAC / DC. 2. Detection range: 110, 15 x 15 m at 25C. 3. Relay output: form C, 5A / NO, 3A / NC resistive. 4. Current drain: standby: 7 mA, Active: 23 mA. 5. High-temp limit 30 / 28 / 26C (85 / 82 / 79F). 6. Low-temp limit 15 / 13 / 11C (59 / 55 / 51F). 7. Mounting height: 1.8 ~ 3.6m. 8. ON delay 0 - 10" - 30" - 1' - 5' - 10' selectable. 9. OFF delay 10" - 1' - 5' - 10' - 20' - 30' selectable. 10. Detectable speed 0.1~ 3 m/sec.(0.3~10 ft/sec.). 11. RFI immunity Av. 20 V/m (10~1,000 MHz). 12. Humidity: 95% RH max. 13. Temperature: -10C~60C (14F~140F). 14. Dimensions 112 x 66 x 45 mm (4.4 x 2.6 x 1.8").

    Features :

    1. High density detection capability.
    2. Form C changeover relay output.
    3. High-low temperature setbacks.
    4. Superior RFI and EMI immunity.
    5. Disabled walk test LED indication.
    6. Optional door switch connectivity.
    7. Wall / corner / ceiling mount available.
    8. 5-minute door open HVAC shut off.
    9. Programmable ON & OFF delay times.
    10. Automatic temperature compensation.

    IR-TEC International Ltd.

    • Taiwan
    主站蜘蛛池模板: 机巴太粗太硬弄死你| 国产精品亚洲精品青青青| 爱情岛论坛首页永久入口| 好妈妈5高清中字在线观看| 午夜精品一区二区三区在线观看 | 精品久久久久久国产| 成人一区专区在线观看| 哦太大了太涨了慢一点轻一点| 中文字幕黄色片| 精品精品国产欧美在线观看| 成人片在线观看地址KK4444| 华人生活自拍区杏吧有你| 一级视频在线免费观看| 真正国产乱子伦高清对白| 女人是男人的未来的人| 亚洲色国产欧美日韩| 91精品国产品国语在线不卡| 欧美成人亚洲欧美成人| 国产福利一区二区| 久久精品亚洲视频| 色综合五月婷婷| 成人三级k8经典网| 人人干视频在线观看| 91久久大香伊蕉在人线| 樱桃视频影院在线观看| 国产孕妇孕交大片孕| 中文无码人妻有码人妻中文字幕| 精品视频一区二区三区在线播放| 好男人社区视频| 亚洲欧美一区二区三区在饯| 男女xx动态图| 日本乱码一卡二卡三卡永久| 可播放的免费男男videos不卡| nanana最新在线视频免费观看网| 欧美黑人巨大xxxxx| 国产清纯91天堂在线观看| 久久九九国产精品怡红院| 精品人妻少妇一区二区三区 | 中文字幕乱码人在线视频1区| 精品久久久一二三区| 国产香蕉精品视频|