  • Power Master Technology Co., Ltd.

    Inverter UPS AVR Charger, DC to DC, DC To AC Power Inverter, UPS, SMR.

    Products

    Online UPS Systems

    ups systems

    • Model No: PM-90120CP
    • Factory Location: Taiwan
    • Sample Request: No
    • Target Markets: Worldwide

    Detail Information

    Description :

    1. Character:
    -Advanced technology of PWM, DSP and IGBT switching components Designed to use a high frequency, highly efficiency DSP/IGBT and PWM technology in converting DC to AC power.
    -True Galvanic isolation design Solve ultimately the problem of power system, including noise, lightning, and leakage current etc.
    -Multi-CPU design and software/hardware cooperate control Make the system extremely high reliable.
    -Plug & Play modular design To allow for each power circuit to be easily removed for quick maintenance and troubleshooting.
    -Each phase with individual inverter supporting Characteristics will not be violated under 100% unbalance load.
    -Protection against detaching and floating of the neutral of input power supply Ensure the safety and stability of the UPS power output.
    -Protection from user error Advanced circuitry prohibits damage to the system when the user makes an operational mistake.
    -Intelligent charger with temperature compensation (option) Prolong the battery life expectancy. And with huge charging power (selectable), can charge very big capacity, long back-up time battery bank.
    -Intelligent, safe battery test circuitry Test the battery without the risk of output AC failure in case of battery bad. And with battery fluid leakage and improper grounding detect circuitry, can ensure safety of the battery bank.
    -Intelligent fan speed control Increase the fan life expectancy and reduce audible noise.
    -Reasonable heat evacuation passage design Main PCBs are designed in a holder to separate the control circuitry and power circuitry. Therefore, the UPS system can operate under harsh environment.
    -Cool start function Can be started without AC mains (with battery only) and protected from high inrush current.
    -Variety of accessory (options) Remote control panel, 3 phases software for PC monitoring, auto dialing module, battery monitoring module, 3 phases SNMP card, and emergency power-off switch are available.
    -Microprocessor design base
    -Mini- remote control panel (option)
    -Multiple output sockets
    -Minimum foot print area design, light weight
    -Built-In AVR for wider input range
    -Auto re-charging whenever AC exist.
    -Hot swappable battery by users
    -RS232 communication port
    -Tel/modem internet surge suppression
    -DC Start function
    -Green power function
    -Auto detecting frequency 12-Pulse Full Controlled Rectifier (option) To reduce total harmonic current and for UPS.

    2. Description:
    3 phase in 3 phase out online UPS.
    Intelligent, digitalized, and true galvanic isolation online design for Power Plants.

    Specification :

    MODELPM-90120CP
    CAPACITYCapacity120KVA / 96KW
    INPUT (RECTIFIER)Input Voltage220 / 380 / 460, 208/ 380, 400, 415
    Input Range±20% ( > ±20% is available upon request)
    Input Frequency50 / 60 Hz ± 5Hz
    Power Walk In0% - 100% : 20 sec
    Efficiency 98%
    Voltage Regulation±1%
    BATTERYBattery Type / PcsMaintenance free lead-acid batteries / 12V x 29pcs
    Maximum Charge
    Current Adc (Selectable)
    60
    Battery StartYes, UPS can be started without AC source.
    INVERTEROutput Voltage220 / 380 / 460, 208 / 380, 400, 415  ± 1 %
    Wave FormSine Wave
    Output Power Factor0.8
    Frequency Lock Range50 / 60 Hz ± 3Hz
    Output Frequency
    (Free Running)
    50 / 60 Hz ± 0.1 Hz
    Phase Shift Under 100% Unbalance Load< 0.5
    THD (Linear Load)< 2 %
    Overload <110%Continuous
    Overload 110-125%15 minutes
    Overload 125-150%10 minutes
    Overload >150%1 minute
    Efficiency (100% Load)95%
    STATIC SWITCHVoltage Range173-277 VAC (L-N)
    Mains ¡÷ Inverter 
    Inverter ¡÷ Mains
    0 ms
    OVERALL CHARACTERISTICSOverall Efficiency93%
    Maximum Heat 
    Dissipation (Kw)
    6.5
    Height x Width x Depth (mm)1600 x 550 x 800
    Weight 
    (Kg, without battery)
    1180
    Audible Noise< 67 dBA (At 1 M)
    Temperature0-40(32-104)
    Humidity0% - 90% (Non-Condensing)
    Altitude 
    EN50091-1,-2YES
    Short Circuit ProtectionYES
    Lightning / EMC FilterMOV / Input&Output (FCC CLASS A)
    Galvanic IsolationInput&Output true Galvanic isolation
    LED, LCD, BuzzerYES
    Remote Control / 
    Communication Interface
    Monitoring 1~99 UPS simultaneously / Dry contact, RS232, RS485

    Power Master Technology Co., Ltd.

    • Taiwan
    主站蜘蛛池模板: 日韩在线国产精品| 绿茶可约可空降直播软件| 日本亚洲精品色婷婷在线影院| 国产XXXX99真实实拍| 一个人看的www在线观看免费| 漂亮华裔美眉跪着吃大洋全集| 国产精品成熟老女人视频| 久久怡红院亚欧成人影院| 美女一级毛片视频| 国精品无码一区二区三区在线 | 99久久无色码中文字幕| 欧美三级韩国三级日本播放 | 久久精品99无色码中文字幕| 精品调教CHINESEGAY| 国产老妇伦国产熟女老妇视频| 久久综合九色综合网站| 精品国产一区二区三区不卡| 国产精品莉莉欧美自在线线| 久久夜色精品国产噜噜麻豆| 精品久久久久久| 国产精品久久久久久搜索| 丰满岳乱妇一区二区三区| 波多野结衣女教师| 国产大尺度吃奶无遮无挡| xxxx日本在线播放免费不卡| 欧美国产一区二区三区激情无套| 国产一卡二卡3卡4卡四卡在线| 99在线国产视频| 日本高清一本视频| 伊人久久大香线蕉综合网站| 国产性夜夜夜春夜夜爽| 男人桶进女人p无遮挡小频| 天天躁日日躁狠狠躁综合| 亚洲午夜国产精品无码 | 欧美xxxx少妇| 台湾swag在线观看| 4hc88四虎www在线影院短视频| 无码日韩精品一区二区免费| 亚洲精品中文字幕乱码| 色综合久久91| 国产精品日日爱|